Industrial Ethernet Cloud router

Industrial Ethernet Cloud router

  • Data acquisition device connected to cloud serves. Supports a two-way data collection channel between the device and the cloud
  • Sets up secure tunnel between the user and the remote device via cloud server, without the need of additional VPN servers
  • Supports MODBUS TCP, MODBUS ASCII/RTU  and MC protocols
  • Firewall functions: Stateful Packet Inspection (SPI), Prevent Denial of Service (DoS) attacks, NAT, port triggering, port mapping, IP address filtering, MAC address filtering, URL filtering
  • Custom alarm conditions with email alarms

Request a quote



Fast Ethernet

  • RJ45 Ports:

                WAN: 1 10/100Base-T(X), auto MDI/MDI-X, auto negotiation

                LAN: 4 10/100Base-T(X), auto MDI/MDI-X, auto negotiation

Serial Communication

  • Serial Ports : 1 RS-232(DB9 male), 1 RS-485( Terminal block), 15KV isolation protection
  • Baud Rate: 2400bps to 115200bps
  • Data Bits: 7, 8
  • Parity: None, Even, Odd
  • Stop Bits: 1, 2
  • Flow Control: RTS/CTS(RS-232 only), XON/XOFF
  • RS-232: TxD, RxD, RTS, CTS, GND
  • RS-485: D+, D-, GND

LEDs

  • Device: PWR, SD, Ready
  • RJ45 Ports: 100M, LINK/ACT
  • Serial Ports: RS-232, RS-485

Reset Button

  • 1set

Cloud Service

  • DIACloud

Software

  • SSH, DNS, HTTP, TFTP, DHCP Server/Client, Telnet, Syslog, MODBUS TCP, NTP, MODBUS RTU/ASCII

Security

  • MAC/IP/URL filtering, SSH, SPI, Prevent denial of service (DoS) attacks, Port triggering, Port mapping

Virtual COM Drivers

  • Windows XP, Windows Vista (32/64 bits), Windows 7 (32/64 bits)

Configuration

  • Web Browser, DIACom, Android APP, iOS APP

POWER REQUIREMENTS

  • Input Voltage: 9to 40VDC, 2 pin terminal block input
  • Input Current: 0.53A Max.
  • Overload Current Protection: Present, Max. Input current 1.5A
  • Reverse Polarity Protection: Not Present

PHYSICAL

  • Housing: IP30 metal case
  • Dimensions: 145.3 mm(H) x 45 mm(W) x 112.3 mm (D)
  • Weight: 308g
  • Installation: Industrial DIN-Rail and Wall mounting

ENVIRONMENTAL LIMITS

  • Operating Temperature : -20℃ to 70℃(-4℉ to 158℉)
  • Storage Temperature: -40℃ to 85℃(-40℉ to 185℉)
  • Ambient Relative Humidity: 5% to 95% (non-condensing)

APPROVALS

  • Safety: UL 60950-1, EN 60950-1
  • EMI: FCC 47 CFR Part 15 Subpart B Class A, EN 55022
  • EMS( EN 55024): IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8
read more ▼

- Data collection device connected to cloud server.

- Support two-way data acquisition channel between device and cloud

- Supports MODBUS TCP and MODBUS RTU / ASCII protocols

- Support NTP time synchronization via network

- Statistics of network data flow

- Diagnose network errors    

read more ▼

Delta